Changing the Industry Through Innovation

Developed in response to the copper shortage following WWII, aluminum building wire had a rocky start right out of the gate. With growing demands for new veteran housing and a booming commercial sector, the subsequent need for building wire was dire. Enter aluminum — a readily available, yet untested alternative to hard-to-find copper wire. What followed was a series of events that tarnished aluminum wire’s image for decades to come.

Here, we will review those events, as well as the solutions put in place that have made it the viable, cost-effective product it was originally intended to be. Keep reading for the whole story… Learn More

Image alt goes here


Products featuring 8000 series Alumaflex® Brand conductors

Southwire SIMPULL THHN cable with AlumaFlex conductors

Southwire's SIMpull THHN® Wire and Cable with Alumaflex® Brand conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2011 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.

Download Catalog Sheet
Features
Southwire SIMpull THHN cable with AlumaFlex conductors

Southwire's SIMpull XHHW® Wire and Cable with Alumaflex® Brand conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the 2011 National Electrical Code. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.

Download CATALOG Sheet
Features
Southwire Type MC Cable

Southwire's Type MC Cable is primarily used for services, feeders, and branch circuits as specified in the 2011 National Electric Code. Type MC cable with Type XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating for XHHW-2 conductors is 600 volts.

Download CATALOG Sheet
Sercice Entrance
Southwire Type SE, service entrance cable

Southwire's Type SE, service entrance cable is used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, it may be used in all applications where Type SE cable is permitted. SE may be used in wet or dry above ground locations at temperatures not to exceed 90° C. The voltage rating is 600 volts.

Download CATALOG Sheet
Sercice Entrance
Southwire Type RHH or RHW-2 or USE-2 conductors

Southwire's Type RHH or RHW-2 or USE-2 conductors are used with conduit as specified in the National Electrical Code. When used as Type USE-2, conductors are suitable for use as underground service entrance conductors for direct burial, at conductor temperatures not to exceed 90°C. When used as RHH, conductor temperatures shall not exceed 90°C in dry locations. When used as RHW-2 or USE-2, conductor temperatures shall not exceed 90°C in wet or dry locations. Voltage rating for RHW-2 or RHH or USE-2 conductors is 600 volts.

Download CATALOG Sheet
Sercice Entrance
Aluminum Photovoltaic(PV)Wire

Southwire's Aluminum Photovoltaic (PC) Wire is used in solar power applications per NEC® Article 690. Rated 90°C for exposed or concealed wiring in wet or dry locations. Rated for direct burial.

Download CATALOG Sheet
Sercice Entrance
Southwire mobile home feeder

Southwire's Aluminum mobile home feeder is intended for the connection of mobile homes to a supply of electricity where permanent wiring is required as specified in the 2011 National Electrical Code. Suitable for direct burial in earth at conductor temperatures not to exceed 90°C. Voltage rating is 600 volts.

Download CATALOG Sheet
Sercice Entrance
Southwire mobile home feeder

Southwire’s triplex Type RHH or RHW-2 or USE-2 Alumaflex® Brand conductors is primarily used for secondary distribution and underground service at 600 volts or less, either directly burial or in ducts, where increased flexibility is needed. May also be used in conduit as specified by the NEC.

Download CATALOG Sheet

*Available upon request only

Sercice Entrance